Open Access

Table 2

Parameters of the coupler.

Symbol Value Parameter
f 150 kHz Operating frequency
D1 200 mm Outer diameter of Tx
D2 100 mm Outer diameter of Rx
d 13 mm Distance between coil
Dfil 2.55 mm Radius of wire
Dsp 1.6 mm Effective radius of wire
N1 8 Number of turns of Tx
N2 2 Number of turns of Rx
Di1 D1–2*N1*Dfil mm Inner diameter of Tx
Di2 D2 − 2*N2*Dfil mm Inner diameter of Rx