Fig. 2

Download original image
Resulting DPSS diagram obtained from least-squares-fitting the TDLS lifetime data shown in Figure 1 using the extracted capture cross section σn (T) = 2.12 × 10−11 × T −1.96. Two solutions are obtained from Chi2-DPSS curve minimum position, Ec − Et = 0.34 eV with k = 1.16 and Et − Ev = 0.34 eV with k = 0. With a smaller Chi2 value by almost two orders of magnitude, the solution in the second half of the bandgap is identified as the true solution.