Issue |
Eur. Phys. J. Appl. Phys.
Volume 33, Number 3, March 2006
|
|
---|---|---|
Page(s) | 213 - 219 | |
Section | Plasma, Discharge and Processes | |
DOI | https://doi.org/10.1051/epjap:2006025 | |
Published online | 04 April 2006 |
https://doi.org/10.1051/epjap:2006025
Light emission from corona discharge in SF6 and SF6/N2 gas mixtures at high pressure
1
LEMD/CNRS, 25 rue des Martyrs, BP 166, 38042 Grenoble Cedex 9, France
2
Laboratoire de Génie Électrique, Université de Guelma, BP 401, 24000 Guelma, Algeria
Corresponding authors: lemzadmi@yahoo.fr andre.denat@grenoble.cnrs.fr
Received:
8
February
2005
Revised:
17
October
2005
Accepted:
20
December
2005
Published online:
4
April
2006
A spectroscopic investigation of corona discharges in SF6/N2 gas mixtures has been undertaken using an optical multichannel analyser (OMA). A point-to-plane geometry has been used with point radii varying from 3 to 10 μm. Spectra are measured for high pressures ranging from 0.2 MPa up to 1.4 MPa and for different concentrations of SF6 in the gas mixture. The spectra in the 200–850 nm spectral range are mainly made of molecular bands, which is indicative of a low temperature discharge. It has been noted that SF6 emits in the region of 420 nm to 510 nm in positive and negative polarities, although in negative polarity the emission is weaker. For SF6/N2 mixtures, the main source of light emission is from N2. The resultant spectra are used to evaluate the rotational Tr and vibrational Tv temperatures of excited N2, Tr being considered, due to the high pressure, to be equal to the kinetic temperature Tkin in the corona discharge. Tr and Tv are determined by comparing the experimental spectrum of the second positive system ( of N2 and the simulated one, which is obtained using a convolution method. As expected, the results show that the measured rotational temperature Tr increases steadily with the mean discharge current, while its increase with gas pressure is less pronounced. The values of Tr are higher for the positive corona discharge than the negative and also for mixtures having higher amounts of SF6. In all conditions, we found and Tv is less sensitive to the variation of the current.
PACS: 52.80.Hc – Glow; corona
© EDP Sciences, 2006
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.