Table 2

Maximum voltage supply (VDC) without breakdown in the various configurations.

  Normal winding Segmented winding
One row turn-to-turn 51094 V 26779 V
One row turn-to-core 1180 V 3368 V
Two rows turn-to-turn 778 V 1725 V
Two rows turn-to-core 903 V 1898 V

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.