Open Access

Table 1

The identified optimal parameters for the two boundary conditions and the corresponding ratio; as defined in the previous section (Eqs. (3)(9)).

Ambient: temperature & humidity (m2)k0 amq bmq pkrl avg bvg c(g/m2s)c
Intrinsic permeability Parameters in Millington & quirk relation Parameters in Van Genuchten equation Convective coefficient
24 °C − 45%RH 7.76 × 10−21 1.975 0.767 0.841 0.248 0.208 90.0 × 10−6
38 °C − 32%RH 10.0 × 10−21 0.792 1.640 2.046 0.192 0.171 2.16 × 10−6
Ratio 0.78 2.49 0.47 0.41 1.29 1.22 41.59