Issue |
Eur. Phys. J. Appl. Phys.
Volume 49, Number 1, January 2010
Focus on Plasma Processes
|
|
---|---|---|
Article Number | 13104 | |
Number of page(s) | 4 | |
Section | Focus on Plasma Processes | |
DOI | https://doi.org/10.1051/epjap/2009195 | |
Published online | 26 November 2009 |
https://doi.org/10.1051/epjap/2009195
Time varying afterglow emission and gas pressure in a pulsed N2 gas microwave flowing discharge at reduced pressure
LAPLACE, Université Paul Sabatier, 118 route de Narbonne, 31062 Toulouse Cedex, France
Corresponding author: ricard@laplace.univ-tlse.fr
Received:
30
June
2009
Revised:
11
September
2009
Accepted:
20
October
2009
Published online:
26
November
2009
Flowing microwave N2 afterglows at reduced pressure are studied as a source of N-atoms. It is presently reported results obtained by pulsing the nitrogen gas flow with an electromagnetic (EM) valve before the plasma, starting with discharge conditions of continuous flow around 1 Torr. By keeping the microwave power tuned on as in continuous flow, it is obtained two successive plasmas: the first one at a pressure of 2–3 Torr when the flow gas is on and the second one at lower pressure (0.4-0.5 Torr) when the flow gas is off. The gas pressures were measured in a 5 L post-discharge chamber. The two plasmas are here analysed by emission spectroscopy and the transmitted powers are deduced from the N2+/N2 intensity ratio for both cases. It is obtained about the same power as for continuous flow when the flow gas is on with a negligible reflected power. The transmitted power is lower and thus the reflected power is important when the flow gas is off. The emission of the N2 1st positive system at 580 nm, signature of the N-atom recombination in the afterglow, is observed in the reactor after the gas pressure rise, with a maximum intensity obtained for a duty cycle of 0.5 at a period of 2 s, corresponding to a maximum N-atom density of about 1015 cm-3 and a pressure variation Δp in the range 2.3-0.5 Torr.
PACS: 82.33.Xj – Plasma reactions / 52.70.-m – Plasma diagnostic techniques and instrumentation
© EDP Sciences, 2009