Articles citing this article

The Citing articles tool gives a list of articles citing the current article.
The citing articles come from EDP Sciences database, as well as other publishers participating in CrossRef Cited-by Linking Program. You can set up your personal account to receive an email alert each time this article is cited by a new article (see the menu on the right-hand side of the abstract page).

Cited article:

Experimental Investigation of the Effect of Conductor Temperature on Corona Performance in Overhead Transmission Lines

Kayumba G. Ilunga, Andrew G. Swanson, Nelson Mutatina Ijumba and Robert Stephen
IEEE Access 12 122114 (2024)
https://doi.org/10.1109/ACCESS.2024.3451980

Experimental and numerical modeling of DC corona discharge in Wire-Cylinder-Plane configuration

Ahmed Kasdi, Sabrina Chouali, Adel Bekakria and Lucian Dascalescu
Journal of Electrostatics 123 103814 (2023)
https://doi.org/10.1016/j.elstat.2023.103814

Electrostatic fog collection mechanism and design of an electrostatic fog collector with nearly perfect fog collection efficiency

Yuan Jiang, Renjie Xu, Siru Liu, Guilian Liu and Xiaohong Yan
Chemical Engineering Science 247 117034 (2022)
https://doi.org/10.1016/j.ces.2021.117034

Investigation of relative humidity effect on the particles velocity and collection efficiency of laboratory scale electrostatic precipitator

H. Nouri, N. Zouzou, L. Dascalescu and Y. Zebboudj
Process Safety and Environmental Protection 104 225 (2016)
https://doi.org/10.1016/j.psep.2016.09.001

Computation and measurement of corona current density and V–I characteristics in wires-to-plates electrostatic precipitator

Ahmed Kasdi
Journal of Electrostatics 81 1 (2016)
https://doi.org/10.1016/j.elstat.2016.02.005

Investigation on the Corona Discharge in Blade-to-Plane Electrode Configuration

Meziane Kaci, Hakim Ait Said, Abdelkrim Laifaoui, et al.
Brazilian Journal of Physics 45 (6) 643 (2015)
https://doi.org/10.1007/s13538-015-0357-4

Effect of relative humidity on current–voltage characteristics of monopolar DC wire-to-plane system

Massinissa Aissou, Hakim Ait Said, Hamou Nouri and Youcef Zebboudj
Journal of Electrostatics 76 108 (2015)
https://doi.org/10.1016/j.elstat.2015.05.019

Analysis of current-voltage characteristics in the wires-to-planes geometry during corona discharge

Hakim Ait Said, Hamou Nouri and Youcef Zebboudj
The European Physical Journal Applied Physics 67 (3) 30802 (2014)
https://doi.org/10.1051/epjap/2014140089

Effect of the experimental parameters on the number of free electrons in the drift region of a wire-cylinder electrostatic precipitator

Audrey Villot, Yves Gonthier, Evelyne Gonze and Alain Bernis
Journal of Electrostatics 71 (4) 815 (2013)
https://doi.org/10.1016/j.elstat.2013.02.004

Analysis of current density and electric field beneath a bipolar DC wires-to-plane corona discharge in humid air

Massinissa Aissou, Hakim Aitsaid, Hamou Nouri and Youcef Zebboudj
The European Physical Journal Applied Physics 61 (3) 30803 (2013)
https://doi.org/10.1051/epjap/2013120172

Characteristics of Styrene Removal With an AC/DC Streamer Corona Plasma System

Xuming Zhang, Jibao Zhu, Xiaoying Li, et al.
IEEE Transactions on Plasma Science 39 (6) 1482 (2011)
https://doi.org/10.1109/TPS.2011.2128351

Numerical Model of Current–Voltage Curve for the Wire-Cylinder Electrostatic Precipitators in Negative Voltage in the Presence of Nonpolar Gases

A Villot, Y F J Gonthier, E Gonze and A Bernis
IEEE Transactions on Plasma Science 38 (8) 2031 (2010)
https://doi.org/10.1109/TPS.2010.2052373

Analysis of positive corona in wire-to-plate electrostatic precipitator

H. Nouri and Y. Zebboudj
The European Physical Journal Applied Physics 49 (1) 11001 (2010)
https://doi.org/10.1051/epjap/2009181

Comparison of Toluene Removal in Air at Atmospheric Conditions by Different Corona Discharges

Milko Schiorlin, Ester Marotta, Massimo Rea and Cristina Paradisi
Environmental Science & Technology 43 (24) 9386 (2009)
https://doi.org/10.1021/es9021816

DC Corona Electric Discharges for Air Pollution Control, 2—Ionic Intermediates and Mechanisms of Hydrocarbon Processing

Ester Marotta, Alessandro Callea, Xianwen Ren, Massimo Rea and Cristina Paradisi
Plasma Processes and Polymers 5 (2) 146 (2008)
https://doi.org/10.1002/ppap.200700128

Unipolar Field and Diffusion Charging in the Transition Regime—Part II: Charging Experiments

A. Marquard, J. Meyer and G. Kasper
Aerosol Science and Technology 41 (6) 611 (2007)
https://doi.org/10.1080/02786820701272061

Calculation and measurement of electric field under HVDC transmission lines

A. Kasdi, Y. Zebboudj and H. Yala
The European Physical Journal Applied Physics 37 (3) 323 (2007)
https://doi.org/10.1051/epjap:2007026

Finite-element analysis of positive and negative corona discharge in wire-to-plane system

N. Oussalah and Y. Zebboudj
The European Physical Journal Applied Physics 34 (3) 215 (2006)
https://doi.org/10.1051/epjap:2006063

Direct monitoring of toxic compounds in air using a portable mass spectrometer

Christopher C. Mulligan, Dina R. Justes, Robert. J. Noll, et al.
The Analyst 131 (4) 556 (2006)
https://doi.org/10.1039/b517541k

Analysis of current and electric field distributions beneath a positive DC wire-to-plane corona

H. Yala, A. Kasdi and Y. Zebboudj
The European Physical Journal Applied Physics 21 (1) 45 (2003)
https://doi.org/10.1051/epjap:2002099

Finite-element solution of monopolar corona in a coaxial system

H. Yala and Y. Zebboudj
The European Physical Journal Applied Physics 19 (2) 123 (2002)
https://doi.org/10.1051/epjap:2002058