Abstract
We investigated the pulsed laser ablation of metallic (Al), semiconductor (Si), and wide bandgap dielectric (LiNbO3) targets in air at normal atmospheric conditions by using 4.5 ns pulses at 532 nm wavelength. We determined the dependence of the ablation rate on the pulse number and laser fluence. The number of consecutive laser pulses hitting the target on the same area was between 5 and 40, and the laser fluence was varied in the range of 10–250 J/cm2 by changing the irradiated area at the target surface. We find that the ablation rate of the three targets is approximately constant when the pulse number is smaller than 15. Further increase of the pulse number leads to a decrease of the ablation rate, the fastest decrease of the ablation rate with pulse number being observed for the dielectric target. The dependence of the ablation rate on the laser fluence indicates two different regimes. In the first regime, which is for values of the fluence smaller than the threshold value (~70 J/cm2 for Al, ~90 J/cm2 for Si, and ~180 J/cm2 for LiNbO3), the ablation rate increases approximately logarithmically with the fluence. In the second regime, characterized by values of the fluence greater than the threshold value, there is a steep increase of the ablation rate. This sudden jump of the ablation rate at the threshold fluence is due to the transition from normal vaporisation to phase explosion, and to the changes in the dimensionality of the plasma-plume hydrodynamics from one-dimensional to three-dimensional.

PACS
42.62.-b - Laser applications.
61.82.Bg - Metals and alloys.
61.82.Fk - Semiconductors.
61.82.Ms - Insulators.

© EDP Sciences 2009


What is OpenURL?

The OpenURL standard is a protocol for transmission of metadata describing the resource that you wish to access. An OpenURL link contains article metadata and directs it to the OpenURL server of your choice. The OpenURL server can provide access to the resource and also offer complementary services (specific search engine, export of references...). The OpenURL link can be generated by different means.
  • If your librarian has set up your subscription with an OpenURL resolver, OpenURL links appear automatically on the abstract pages.
  • You can define your own OpenURL resolver with your EDPS Account. In this case your choice will be given priority over that of your library.
  • You can use an add-on for your browser (Firefox or I.E.) to display OpenURL links on a page (see http://www.openly.com/openurlref/). You should disable this module if you wish to use the OpenURL server that you or your library have defined.